National Repository of Grey Literature 6 records found  Search took 0.01 seconds. 
Mapping of motion artefact in fMRI
Nováková, Marie ; Kremláček, Jan (referee) ; Jan, Jiří (advisor)
This thesis summarizes a theory of magnetic resonance and the method of functional magnetic resonance. It is focused on the influence of motion artifacts and image preprocessing methods, especially realign. It deals with the possibility of using movement parameters obtained in the process of alignment of functional scans to create maps that show the expression of motion artifacts. In this thesis, three different methods were designed, implemented a tested. These methods lead to the creation of probability, power and statistical group maps showing areas typically affected by movement artifacts.
Analysis of connections between simultaneous EEG and fMRI data
Labounek, René ; Kremláček,, Jan (referee) ; Lamoš, Martin (advisor)
Electroencephalography and functional magnetic resonance are two different methods for measuring of neural activity. EEG signals have excellent time resolution, fMRI scans capture records of brain activity in excellent spatial resolution. It is assumed that the joint analysis can take advantage of both methods simultaneously. Statistical Parametric Mapping (SPM8) is freely available software which serves to automatic analysis of fMRI data estimated with general linear model. It is not possible to estimate automatic EEG–fMRI analysis with it. Therefore software EEG Regressor Builder was created during master thesis. It preprocesses EEG signals into EEG regressors which are loaded with program SPM8 where joint EEG–fMRI analysis is estimated in general linear model. EEG regressors consist of vectors of temporal changes in absolute or relative power values of EEG signal in the specified frequency bands from selected electrodes due to periods of fMRI acquisition of individual images. The software is tested on the simultaneous EEG-fMRI data of a visual oddball experiment. EEG regressors are calculated for temporal changes in absolute and relative EEG power values in three frequency bands of interest ( 8-12Hz, 12-20Hz a 20-30Hz) from the occipital electrodes (O1, O2 and Oz). Three types of test analyzes is performed. Data from three individuals is examined in the first. Accuracy of results is evaluated due to the possibilities of setting of calculation method of regressor. Group analysis of data from twenty-two healthy patients is performed in the second. Group EEG regressors analysis is realized in the third through the correlation matrix due to the specified type of power and frequency band outside of the general linear model.
Inverse values of EEG signal power in joint EEG-fMRI analysis
Sanetrníková, Dominika ; Kolář, Radim (referee) ; Labounek, René (advisor)
The first part of this thesis summarizes the basic theory of brain activity measurement using the BOLD signal and scalp EEG, the effect of noise phenomena in the data and its suppression, the merger of the fusion of the measured data using the general linear model and the current implementation of computational algorithms in the software library EEG Regressor Builder 1.0. Within the own solution of this thesis, the changes of the software library to version 1.1 were realized according to the requirements of the bachelor thesis. The hypothesis that temporal changes of the EEG relative band power (20 - 40Hz) has the same spatial correlates with the BOLD signal as the inverse power in the frequency range 0-12Hz. The hypothesis was rejected based on the calculation of similarity criterions between 3D activation maps for different parameter settings of the joint analysis calculations. As an appropriate criterions were chosen the correlation coefficient and the cosine criterion. The Euclidean distance was proved to be unfit. Also it was proved the inverse power value of EEG signal in the given frequency band brings to the common EEG-fMRI analysis an anti-correlated signal to the normal absolute power in the same frequency band. Furthermore the influence of regressors describing motion artifacts reduces the number of supra-thresholded voxels.
Inverse values of EEG signal power in joint EEG-fMRI analysis
Sanetrníková, Dominika ; Kolář, Radim (referee) ; Labounek, René (advisor)
The first part of this thesis summarizes the basic theory of brain activity measurement using the BOLD signal and scalp EEG, the effect of noise phenomena in the data and its suppression, the merger of the fusion of the measured data using the general linear model and the current implementation of computational algorithms in the software library EEG Regressor Builder 1.0. Within the own solution of this thesis, the changes of the software library to version 1.1 were realized according to the requirements of the bachelor thesis. The hypothesis that temporal changes of the EEG relative band power (20 - 40Hz) has the same spatial correlates with the BOLD signal as the inverse power in the frequency range 0-12Hz. The hypothesis was rejected based on the calculation of similarity criterions between 3D activation maps for different parameter settings of the joint analysis calculations. As an appropriate criterions were chosen the correlation coefficient and the cosine criterion. The Euclidean distance was proved to be unfit. Also it was proved the inverse power value of EEG signal in the given frequency band brings to the common EEG-fMRI analysis an anti-correlated signal to the normal absolute power in the same frequency band. Furthermore the influence of regressors describing motion artifacts reduces the number of supra-thresholded voxels.
Mapping of motion artefact in fMRI
Nováková, Marie ; Kremláček, Jan (referee) ; Jan, Jiří (advisor)
This thesis summarizes a theory of magnetic resonance and the method of functional magnetic resonance. It is focused on the influence of motion artifacts and image preprocessing methods, especially realign. It deals with the possibility of using movement parameters obtained in the process of alignment of functional scans to create maps that show the expression of motion artifacts. In this thesis, three different methods were designed, implemented a tested. These methods lead to the creation of probability, power and statistical group maps showing areas typically affected by movement artifacts.
Analysis of connections between simultaneous EEG and fMRI data
Labounek, René ; Kremláček,, Jan (referee) ; Lamoš, Martin (advisor)
Electroencephalography and functional magnetic resonance are two different methods for measuring of neural activity. EEG signals have excellent time resolution, fMRI scans capture records of brain activity in excellent spatial resolution. It is assumed that the joint analysis can take advantage of both methods simultaneously. Statistical Parametric Mapping (SPM8) is freely available software which serves to automatic analysis of fMRI data estimated with general linear model. It is not possible to estimate automatic EEG–fMRI analysis with it. Therefore software EEG Regressor Builder was created during master thesis. It preprocesses EEG signals into EEG regressors which are loaded with program SPM8 where joint EEG–fMRI analysis is estimated in general linear model. EEG regressors consist of vectors of temporal changes in absolute or relative power values of EEG signal in the specified frequency bands from selected electrodes due to periods of fMRI acquisition of individual images. The software is tested on the simultaneous EEG-fMRI data of a visual oddball experiment. EEG regressors are calculated for temporal changes in absolute and relative EEG power values in three frequency bands of interest ( 8-12Hz, 12-20Hz a 20-30Hz) from the occipital electrodes (O1, O2 and Oz). Three types of test analyzes is performed. Data from three individuals is examined in the first. Accuracy of results is evaluated due to the possibilities of setting of calculation method of regressor. Group analysis of data from twenty-two healthy patients is performed in the second. Group EEG regressors analysis is realized in the third through the correlation matrix due to the specified type of power and frequency band outside of the general linear model.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.